Specification Of BECafzar Co. inverter
Mechanical
characteristics :
-
Metal Sheet
cabinet ,
-
IP 42
-
Paint:
RAL7032 light grey (electro-static powder coated
painting)
-
Lifting eye
-
Identification plate outside of Cabinet
-
Cable entry
: bottom , with gland plate
-
Standard
tags for all of wires
-
Standard
label for all of components
|
Electrical
characteristics :
-
Nominal
input voltage:
-
220VDC
+15%,-15%
-
Inverter
output :
-
Nominal
voltage( Un): 220V:
-
Nominal
capacity : 10KVA ,
15KVA , 20KVA, 25KVA,30KVA
-
Nominal
frequency: 50Hz
-
Voltage
regulation:
-
Static: 2%
-
Dynamic :
-
-load
variation with 10%
steps : output variation 2%
-
-load
variation with
50%(50 to 100%) steps : output variation 5%
-
output
voltage will be stable within 100msec.
-
Long term
stability of Un
-
Efficiency: > 85%
-
Output
power factor : 0.80
Frequency
Variation:
THD :
Over
load:
Protections
-
Polarity
reversal of input DC voltage
-
DC soft
rise in the input of Inverter
-
Short
circuit ( fast fuse protistor) and electronic cut
out
-
Over load
protection on inverter line and bypass line
-
Fast fuses
for power modules protection DC input
-
MCCB (mounded
case circuit breaker) for DC IN/bypass IN/manual
bypass IN/output
-
Low DC
input ( disconnect input section from DC source
and transfer output to bypass line)
-
DC input
high ( disconnect input section from DC source and
transfer output to bypass line)
-
Low /high
inverter output voltage
-
Inverter
output frequency out of range.
-
Low /high
bypass line voltage
-
Bypass
line frequency out of range.
-
Over
temperature alarm
-
Inverter
over temperature shutdown ( load will transfer to
bypass line)
Environmental
Ambient
temperature:
Measurements
:
-
Output Voltage (AC
voltmeter 0-500V class 1.5)
-
Output Current (AC
Amper meter class 1.5)
-
Input Voltage
(linear DC Volt meter 0-300V class 1.5)
-
Input Current
(linear DC Amprer meter class 1.5)
-
Output frequency
System status
indicators and Alarms:
-
LEDs
located on PCBs
-
LED for
inverter output High voltage.
-
LED for
inverter output Low voltage.
-
LED for
inverter freq. fail
-
LED for
inverter not sync.
-
LED for
inverter Over load .
-
LED for
DC input low voltage.
-
LED for
DC input High voltage.
-
LED for
over temperature.
-
LED for
bypass line low
-
LED for
bypass line high
-
LED for
bypass frequency fail
-
LED for
bypass line overload
-
LEDs
located on mimic panel
-
LED for DC
OK
-
LED for
INV OK
-
LED for
bypass OK
-
LED for
SSI ON
-
LED for
SSB ON
-
LED for
manual bypass switch ON
-
LED for
output switch ON
-
LED for
general fault
Switches
located on front panel:
-
Reset
switch for buzzer
-
Lamp test
Remote
alarms
Audible
alarm
with constable circuit and alarm silence push
button
Static
switch system
Manual